Chapter
387
23
Switcher Setup
Setting the Switcher
Configuration
Setting a Switcher Bank
Assigning a logical M/E
You can set which hardware block (physical block) of the
switcher is handled logically as an M/E.
You can assign M/E-1 to M/E-5 or P/P.
• When M/E split is enabled, you can configure each sub
bl
ock.
• It is not possible to assign the same M/E logical bank
mor
e than once.
• When a hardware block (physical block) is handled as
a mu
lti viewer, an M/E cannot be assigned.
• Boxes that are not configured in the switcher are not
di
splayed.
1
Open the Home > Setup > Switcher > Config > M/E
Assign menu (19103.11).
2
Select the [Logical Box ID] tab, switch boxes, and
select the target physical M/E block/sub block to set.
3
Press the [M/E] button and select a logical M/E
(M/E-1 to M/E-5, P/P) from the pull-down list.
Setting sub block full keys
When M/E split is enabled, you can configure the number
of keys assigned to each sub block.
1
Open the Home > Setup > Switcher > Config > M/E
Assign menu (19103.11).
2
Select the [Logical Box ID] tab, switch boxes, and
select the target sub block to set.
3
Press the [No.of full keys] button and select the
number of full keys from the pull-down list.
When the system signal format is 2160P, you can
sel
ect 0, 2, or 4.
When the system signal format is 1080P or 1080i,
you
can select 0, 2, 4, 6, or 8.
Setting sub block key additional keys
When M/E split is enabled, you can configure the number
of keys assigned to each sub block.
When the system signal format is 2160P, up to two
addi
tional keys can be used. However, when the system
signal format is 1080P or 1080i, they cannot be used.
1
Open the Home > Setup > Switcher > Config > M/E
Assign menu (19103.11).
2
Select the [Logical Box ID] tab, switch boxes, and
select the target sub block to set.
3
Press the [No. of add keys] button and select the
number of additional keys from the pull-down list.
When the system signal format is 2160P, you can
sel
ect 0, 1, or 2.
Setting an SL key
An SL key can be used if the number of keys on a single
physical M/E block/sub block is four or lower.
Only one physical M/E block/sub block can use an SL
key.
To use the SL key function, the MZS-X1620 SL Key
Li
cense (option) is required.
Also, when the system signal format is 2160P, the SL key
must
be enabled.
1
Open the Home > Setup > Switcher > Config > M/E
Assign menu (19103.11).
Notes
Note
Note