INSTALLATION
Reverse removal procedure to install solenoid valves and noting
the following points.
For details of solenoid valve installation, refer to “Unit Repair”
section. Use new gasket and O-ring.
Install oil tubes in such order as shown in figure.
For details of oil pan installation, refer to “Unit Repair” section.
Use new oil pan gasket.
Tighten universal joint flange bolts & nuts and exhaust pipe brack-
et bolts to specified torque.
Fill A/T fluid and check fluid level according to procedure de-
scribed in “CHANGING FLUID” previously.
Check for fluid leakage after warming up A/T.
THROTTLE POSITION SENSOR
INSPECTION
Refer to SECTION 6E1/6E2 for inspection.
POWER/NORMAL CHANGE SWITCH
INSPECTION
Check Power/Normal change switch for operation referring to Step
4 of Diag. Flow Table B-4 in this section.
If malfunction is found, replace.