2.2.3 Partial arming (system with zones only)
Proceed as follows to arm the alarm system partially if no areas are defined:
1) Enter < Master / User code / Installer / Tech. Manager > and press
2) The keypad will beep. Press
to exit without arming.
3) Enter the number of the zones to be armed on the keypad: the respective squares will
turn black.
IMPORTANT! Simply enter the number directly if nine or fewer zones have been programmed. If more than
nine zones have been programmed, always enter two digits to select the zones, including for numbers from 1
to 9 (1 = 01, 2 = 02 etc.).
4) The status LED will light up after 5 seconds (fixed if all zones are armed, blinking if
some zones are not armed). Press again if you do not want to wait for 5
seconds.
5) If programmed or if the system is EN50131 compliant, the keypad will sound long beeps
initially followed by short beeps for the last 10 seconds.
6) The display will go back to standard view automatically after one minute. Press
to go to standard view immediately.
IMPORTANT! The user will arm only the assigned zones and not necessarily all the zones even with this procedure.
2.2.4 Partial arming (system with areas and zones)
Proceed as follows to arm the entire alarm system if areas are defined:
1) Enter < Master / User code / Installer / Tech. Manager > and press
.
2) Enter
or on the keypad. The procedure will continue as for zones only if you
press . If you press :
3) The keypad will beep. Press
to exit without arming.
4) Enter the number of the areas to be armed on the keypad: the respective squares will
turn black.
5) The status LED will light up after 5 seconds (fixed if all areas are armed, blinking if
some areas are not armed) and all the areas will appear on the display. Press
again if you do not want to wait for 5 seconds.
6) If programmed or if the system is EN50131 compliant, the keypad will sound long beeps
initially followed by short beeps for the last 10 seconds.
7) I The display will go back to standard view automatically after one minute. Press
to
go to standard view immediately.
IMPORTANT! The user will arm only the assigned areas and not necessarily all the areas even with this procedure.
ARM
□□□□••••••••••••
EXECUTED
■□□■••••••••••••
1)AREAS
2)ZONES
ARM
□□••
EXECUTED
■□••