DS1067-062C 50 LBT20063
4.2.10 Detector jamming alarm
Monitoring of devices provided with fault output can be implemented in combination on control panels.
This is generated
when...
If one or more customised jamming inputs are open.
It activates...
The programmed detector fault outputs which have at least one zone in common with the input
which generated the event (with zone armed).
The dialler to send the respective alarm message (if programmed) in form of numeric code,
vocal call or modem communication.
It is stored...
In the Diagnose Log and in the fault and anomaly memory.
It is indicated...
On fault LED of keypads which have at least one zone in common with the input which
generated the event.
On readers which have at least one zone in common with the input which generated the event.
After having solved
the problem, the
control panel...
Stores end of fault in the Diagnose Log.
Deactivates the programmed fault detector outputs.
4.2.11 Detector fault alarm
Monitoring of devices provided with fault output can be implemented in combination on control panels.
This is generated
when...
If one or more customised detector fault inputs are open
It activates...
The programmed detector fault outputs which have at least one zone in common with the input
which generated the event (with zone armed).
The dialler to send the respective alarm message (if programmed) in form of numeric code,
vocal call or modem communication.
It is stored...
In the Diagnose Log and in the fault and anomaly memory.
It is indicated...
On fault LED of keypads which have at least one zone in common with the input which
generated the event.
On readers which have at least one zone in common with the input which generated the event.
After having solved
the problem, the
control panel...
Stores end of fault in the Diagnose Log.
Deactivates the programmed fault detector outputs.
4.2.12 Faulty siren alarm
Monitoring of devices provided with fault output can be implemented in combination on control panels.
This is generated
when...
One or more customised siren fault inputs are open
It activates...
The programmed system fault outputs which have at least one zone in common with the input
which generated the event.
The dialler to send the respective alarm message (if programmed) in form of numeric code,
vocal call or modem communication.
It is stored...
In the Diagnose Log and in the fault and anomaly memory.
It is indicated...
On fault LED of keypads which have at least one zone in common with the input which
generated the event.
On readers which have at least one zone in common with the input which generated the event.
After having solved
the problem, the
control panel...
Stores end of fault in the Diagnose Log.
Deactivates the programmed failure outputs.