DS1067-062C 31 LBT20063
2.9.2 Total disarming from proximity key reader
2.9.2.1 System in use mode = Mode 3 (EN50131 grade 3 compliant)
Proceed as follows to disarm all zones assigned to the reader and to the key using the proximity key:
1. Approach the proximity key to the transponder. The red LED will blink to indicate that the key is being read and the
green LED will light up after a few instants to indicate that the key was recognised. All the green LEDs will blink rapidly
if the key is not recognised.
2. The green LEDs corresponding to any armed zones will light up if the key is recognised (the procedure will disarm the
zones if any green LEDs are on). The red LED will keep blinking.
3. Move the key away.
4. Approach the proximity key again when the red LED switches off.
5. Move away the proximity key when the red LED starts blinking.
6. The green LEDs will indicate the status of the zones assigned to the reader for a few seconds: LED off = zone
disarmed, LED on = key not assigned to the zone. The possibility of disarming each zone depends on the
programming of the reader and on the key used.
IMPORTANT! The key will disarm only the assigned areas and not necessarily all the areas even with this
procedure.
2.9.2.2 System in use mode = Mode 2
Proceed as follows to disarm all zones assigned to the reader and to the key using the proximity key:
1. Approach the proximity key to the transponder. The red LED will blink to indicate that the key is being read. All the
green LEDs will blink rapidly if the key is not recognised.
2. Move away the proximity key from the transponder when the red LED starts blinking.
3. The green LEDs indicate the status of the zones assigned to the reader. LED off = zone disarmed, LED on = key not
assigned to the zone. The possibility of disarming each zone depends on the programming of the reader and on the
key used.
IMPORTANT! The key will disarm only the assigned zones and not necessarily all the zones even with this
procedure.
2.9.3 Total disarming from 1067/026 keypad
Proceed as follows to disarm all zones using the proximity key on a:
1) Approach the proximity key to the proximity key reader.
2) The keypad will beep. Press
to exit without disarming.
3) After 5 seconds, the status LED will switch off and the squares will become empty
indicating that the zones have been disarmed. The following will appear on the display.
IMPORTANT! The key will disarm only the assigned zones and not necessarily all the zones even with this
procedure.
IMPORTANT! The LED H (see Figure 3 – 1067/026 keypad) will light up and the buzzer will sound to indicate an
error (long beep) if a key which can be not been acquired (the key is not recognised) or which has not been enabled
is used.
2.9.4 Partial disarming from electronic key reader
Follow the same procedure used for partial arming from electronic key reader to partially disarm the system from an
electronic key reader.
2.9.5 Partial disarming from proximity key reader
Follow the same procedure used for partial disarming from proximity key reader to partially disarm the system with a
proximity key reader.
EXECUTED
DISARM
ZONES

Table of Contents

Other manuals for urmet domus 1067

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the urmet domus 1067 and is the answer not in the manual?

urmet domus 1067 Specifications

General IconGeneral
Brandurmet domus
Model1067
CategoryAntenna
LanguageEnglish

Related product manuals