4.3.15 Arrest system event
This is generated
when...
• There is no mains power and the battery is not sufficiently charged (≤ 10.5 V)
It is indicated …
• On Power LED off.
It is stored...
• In the Diagnose Log (if the battery is not yet completely flat).
4.3.16 Valid code entered by user on keypad event
This is generated
when...
• A valid access code is entered.
It is stored...
• In the Event Log and the Diagnose Log.
4.3.17 Edit date-time on keypad event
This is generated
when...
• The date and time is edited.
It is stored...
• In the Event Log and the Diagnose Log.
4.3.18 User code enable/disable event
This is generated
when...
• An access code is enabled or disabled.
It is stored...
• In the Event Log and the Diagnose Log.
4.3.19 Key enable/disable event
This is generated
when...
• An electronic or proximity key is acquired or deleted.
It is stored...
• In the Event Log and the Diagnose Log.
4.3.20 Key acquisition/deletion event
This is generated
when...
• An electronic or proximity key is acquired or deleted.
It is stored...
• In the Event Log and the Diagnose Log.
4.3.21 Timed programmer warning event
This is generated
when...
• The timed programmer will arm the zones soon.
It activates...
• The programmed PO warning outputs (only if the control concerns the zone status).
• The enabled and associated keypads (buzzer).
It is indicated …
• On Timed programmer LED (only if the command concerns zone status).
4.3.22 Arming block event
This is generated
when...
• Arming is blocked, e.g. because inputs are open.
It is stored...
• In the Event Log and the Diagnose Log.
4.3.23 Arming not executed event
This is generated
when...
• If one or more zones are not armed because of severe system anomalies.
It activates...
• The dialler to send the incomplete zone arming message in form of numeric code (if
programmed).
It is stored...
• In the Event Log and the Diagnose Log.