4.2 DESCRIPTION OF ALARMS AND INDICATIONS
4.2.1 Burglar alarm
This alarm is generated in case of burglar attempts. The control panels can manage one burglar alarm per zone, to which
output actuators, such as sirens, can correspond.
The burglar inputs generate an alarm when the programmed conditions are respected: break-in detected by one or more
devices, one or more detections, according to a given route etc..
The "Alarm Count" function determines a maximum number of alarms which can be caused by a detector during one day
and as long as the respective zone is armed.
IMPORTANT! The “Alarm Count” function is activated and configured to comply with EN50131 grade 2 by default on
1067/024 control panel. Changing this configuration will cancel EN50131 grade 2 compliance of the system.
IMPORTANT! The “Alarm Count” function is activated and configured to comply with EN50131 by default on
1067/032A and 1067/052A control panels. Changing this configuration will cancel EN50131 compliance of the
system.
This is generated
when...
A burglar input is opened and at least one zone associated to it with OR function is armed.
A burglar input is opened and all zones associated to it with AND function are armed.
It activates...
The programmed burglar outputs which have at least one zone in common with the input
which generated the event.
Activates the dialler to send the respective burglar alarm message (if programmed) in form of
numeric code, vocal call, text message or modem communication.
It is stored ...
In the Event Log and the Diagnose Log.
In the Alarms Memory.
It is indicated ...
On keypads which have at least one zone in common with the input.
On readers which have at least one zone in common with the input.
It lasts ...
For the burglar/tamper/panic alarm time.
It is stopped by...
Entering a valid code on the keypad which has at least one zone in common with the input
which generated the event.
Inserting a valid key which has at least one zone in common with the input which generated
the event.
Imparting a disarm zone command from key input which has at least one zone in common with
the input which generated the event.
Imparting a disarm zone command from vocal menu.
Imparting a disarm command from remote control which has at least one zone in common with
the input which generated the event.
4.2.2 Burglar pre-alarm
The burglar pre-alarm function can be used in the system, for example, to sound a buzzer whenever the detectors of an
external area, e.g. a yard, detect the presence of a person.
This is generated
when...
A pre-alarm input is opened and at least one zone associated to it with OR function is armed.
A pre-alarm input is opened and all zones associated to it with AND function are armed.
It activates...
The programmed pre-alarm outputs which have at least one zone in common with the input
which generated the event.
The dialler to send the respective pre-alarm message (if programmed) in form of numeric
code, vocal call, text message or modem communication.
It is stored ...
In the Event Log and the Diagnose Log.
In the temporary Alarms Memory.
It is indicated ...
On keypads which have at least one zone in common with the input.
On readers which have at least one zone in common with the input.
It lasts ...
For the pre-alarm time.
It is stopped by...
Entering a valid code on the keypad which has at least one zone in common with the input
which generated the event.
Inserting a valid key which has at least one zone in common with the input which generated
the event.
Imparting a disarm zone command from key input which has at least one zone in common with
the input which generated the event.
Imparting a disarm command from remote control which has at least one zone in common with
the input which generated the event.

Table of Contents

Other manuals for urmet domus 1067

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the urmet domus 1067 and is the answer not in the manual?

urmet domus 1067 Specifications

General IconGeneral
Brandurmet domus
Model1067
CategoryAntenna
LanguageEnglish

Related product manuals