DS1067-062C 59 LBT20063
5.1.1 Default access code
The 1067/024, 1067/032A and 1067/052A control panels are provided with default codes when they leave the factory.
The Installer and Technical Manager codes are enabled at the factory and automatically deactivated when a valid Master
or User code is entered for the first time.
Code type Level Default code Assigned Zones
Enabled when
leaving the factory
Enable time
(once enabled)
Installer 3 000000 All Yes Temporary session
Master 2 111111 All Yes Permanent
User (2÷14)
2 000020-000140 Zone 1 No
Until expressly
disabled
Technical
Manager
3 222222 All Yes Temporary session
Table 11 - Default access codes for 1067/024
Code type Level Default code Assigned Zones
Enabled when
leaving the factory
Enable time
(once enabled)
Installer 3 000000 All Yes Temporary session
Master 2 111111 All Yes Permanent
User (2 ÷31)
2 000020-000310 Zone 1 No
Until expressly
disabled
Technical
Manager
3 222222 All Yes Temporary session
Table 12 - Default access codes for 1067/032A
Code type Level Default code Assigned Zones
Enabled when
leaving the factory
Enable time
(once enabled)
Installer 3 000000 All Yes Temporary session
Master 2 111111 All Yes Permanent
User (2 ÷62)
2 000020-000620 Zone 1 No
Until expressly
disabled
Technical
Manager
3 222222 All Yes Temporary session