DS1067-062C 57 LBT20063
4.4 DESCRIPTION OF ACOUSTIC INDICATIONS
If appropriately programmed, the keypads can emit auditory indications following given events.
4.4.1 Entry/exit time indication
This is generated
when...
One or more zones associated to the keypads on which this function is enabled are armed (exit
time).
One or more areas with one or more associated zones with this function enabled are armed
(exit time).
An input is opened (e.g. a customised first entry input) (entry time).
It lasts...
For the zone entry/exit time or the delayed input delay time.
It is activated on...
Enabled and associated keypads.
The programmed buzzer outputs which have at least one zone in common with the arming
input.
IMPORTANT! The entry/exit acoustic indication function is activated and configured to comply with EN50131 by
default on control panels. Changing this mandatory configuration will cancel EN50131 compliance of the system.
4.4.2 Arming warning
This is generated
when...
The programmed warning time for executing a zone arming command by the timed programmer
is elapsing.
It lasts...
For until the zones are armed or a postpone command is imparted.
It is activated on...
Enabled and associated keypads with one beep per minute.
The programmed arming warning outputs which have at least one zone in common with the
arming input.
4.4.3 Gong
This is generated
when...
An input on which the ancillary gong function was enabled is opened and all the zones to which it
is associated are disarmed.
It is activated on...
Enabled and associated keypads with two consecutive beeps.
Programmed gong outputs which have at least one zone in common for one second.
4.4.4 System status by means of wireless sirens
Some sirens can indicate the system status, i.e. arming and disarming by means of the remote control or other means,
either local or remote. The behaviour is comparable to that of car anti-theft systems which indicate arming and disarming
by beeping and flashing the indicators.
This is generated
when...
One or more zones or the entire system is armed/disarmed (if appropriately programmed).
It is activated on...
Sirens inside and outside the system.
It is indicated...
Sirens by means of auditory only or auditory-visual indication:
1058/405 arming = 1 beep + 1 lampeggio; disarming = 2 beep + 1 sequential blink

Table of Contents

Other manuals for urmet domus 1067

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the urmet domus 1067 and is the answer not in the manual?

urmet domus 1067 Specifications

General IconGeneral
Brandurmet domus
Model1067
CategoryAntenna
LanguageEnglish

Related product manuals