DS1067-062C 21 LBT20063
7) The display will go back to standard view automatically after one minute after arming
both areas and zones. Press to go to standard view immediately.
8) For arming both areas and zones, if programmed or if the system is EN50131
compliant, the keypad will sound long beeps initially followed by short beeps for the
last 10 seconds.
2.3.3 Partial arming (system with zones only)
Proceed as follows to arm the entire alarm system partially if no areas are defined:
1) Enter < Master / User code / Installer / Tech. Manager > and press
.
2) The keypad will beep. Press to exit without arming.
3) Enter the number of the zones to be armed on the keypad: the respective squares will become full.
IMPORTANT! Simply enter the number directly if nine or fewer zones have been programmed. If more than
nine zones have been programmed, always enter two digits including for numbers from 1 to 9 (1 = 01, 2 =
02 etc.).
4) The status LED will light up after 5 seconds (fixed if all zones are armed, blinking if only
some zones are armed). The square will appear full indicating the zones which have
been armed. The following will appear on the display:
IMPORTANT! The user will arm only the assigned zones and not necessarily all the zones even with this
procedure.
5) The display will go back to standard view automatically after one minute. Press
to go to standard view immediately.
6) If programmed or if the system is EN50131 compliant, the keypad will sound long
beeps initially followed by short beeps for the last 10 seconds.
2.3.4 Partial arming (system with areas and zones)
Proceed as follows to arm the entire alarm system partially if areas are defined:
1) Enter < Master / User code / Installer / Tech. Manager > and press
.
2) Press T1 for areas or T4 for zones. Press T1 (i.e. areas) on the display. An empty
square will appear for each programmed area which is not armed assigned to the
keypad and code. Full squares indicate that the area is armed. Half-full squares
indicate that the area is only partially armed.
3) The keypad will beep. Press
to exit without arming.
4) Press the function keys (T1, T2, T3 e T4) positioned under the areas to be armed: the
respective squares of the areas will become full.
5) The status LED will light up after 5 seconds (fixed if all areas are armed, blinking if
some areas are not armed). The following will appear on the display:
6) Press
again if you do not want to wait for 5 seconds.
IMPORTANT! The user will arm only the assigned areas and not necessarily all the
areas even with this procedure.