4.2.13 Failure alarm from failure input
Monitoring of devices provided with fault output can be implemented in combination on control panels.
This is generated
when...
• A programmed failure input is opened.
The alarm is generated regardless of zone status (H24).
It activates...
• The programmed failure outputs which have at least one zone in common with the input which
generated the event.
• The dialler to send the respective alarm message (if programmed) in form of numeric code,
vocal call or modem communication.
It is stored...
• In the Event Log and the Diagnose Log.
• In the faults and anomalies list.
It is indicated...
• On fault LED of keypads which have at least one zone in common with the input which
generated the event.
• On readers which have at least one zone in common with the input which generated the event.
It is stopped by...
• Closing the programmed failure input again.
After having solved
the problem, the
control panel...
• Activates the dialler to send the respective failure alarm message (if programmed) in form of
numeric code, vocal call, text message or modem communication.
• Stores end of fault in the Event Log.
• Deactivates the programmed failure outputs.
4.2.14 System failure alarm
This is generated
when...
• An anomaly concerning the system power occurs.
• An anomaly concerning the battery charging circuit occurs.
• An anomaly concerning the sirens occurs.
• An anomaly concerning the supplementary power supply occurs.
The alarm is generated regardless of zone status (H24).
It activates...
• The programmed system failure outputs.
• The dialler to send the respective alarm message (if programmed) in form of numeric code,
vocal call or modem communication.
It is stored...
• In the Diagnose Log and in the fault and anomaly memory.
It is indicated...
• On the yellow fault LED on the keypads.
It is stopped by...
• Solving the problem.
After having solved
the problem, the
control panel...
• Stores end of fault in the Diagnose Log.
• Activates the dialler to send the respective end of failure alarm message (if programmed) in
form of numeric code, vocal call or modem communication.
• Deactivates the programmed system failure outputs.
4.2.15 External communicator failure alarm
This is generated
when...
• An external communicator failure input is opened.
The alarm is generated regardless of zone status (H24).
It activates...
• The programmed communicator failure outputs.
• The dialler to send the respective alarm message (if programmed) in form of numeric code,
vocal call or modem communication.
It is stored...
• In the Diagnose Log and in the fault and anomaly memory.
It is indicated...
• On the yellow fault LED on the keypads.
• On the red LED of the readers.
It is stopped by...
• Solving the problem.
After having solved
the problem, the
control panel...
• Stores end of fault in the Diagnose Log.
• Activates the dialler to send the respective end of failure alarm message (if programmed) in
form of numeric code, vocal call or modem communication.
• Deactivates the programmed tel. failure outputs.