4.3.10 Isolated input event
This is generated
when...
The inputs are isolated manually.
It activates...
The programmed isolated input outputs which have at least one zone in common with the
isolated input.
The dialler to send the isolated inputs message in form of numeric code (if programmed).
It is indicated...
On the yellow isolated inputs LEDs on the keypads which have at least one zone in common
with the isolated input.
It is stored...
In the Event Log and the Diagnose Log.
In the isolated input list.
At the end of input
isolation, the control
panel...
Stores the end of input isolation event in the Event Log and in the Diagnose Log.
Deactivates the programmed isolated input outputs associated to the zones which have no more
isolated inputs.
Switches off the yellow isolated inputs LEDs on keypads associated to the zones which have
no more isolated inputs.
4.3.11 Arm/disarm zones event
This is generated
when...
One or more zones are armed.
One or more zones are disarmed.
It activates...
The programmed zone status outputs and at least one zone armed by overriding, the RM AND
outputs and the RM OR outputs.
The dialler to send the zone armed and disarmed message (if programmed) in form of numeric
code, vocal call or text message.
It is indicated …
On Status LED on keypads associated to at least one concerned zone.
It is stored...
In the Event Log and the Diagnose Log.
4.3.12 Arm/disarm zones override event
This is generated
when...
The arming of one or more zones is overridden (e.g. because there are open inputs).
It activates...
l The programmed zone status outputs and at least one zone armed by overriding, the RM AND
outputs and the RM OR outputs.
The dialler to send the zone armed and disarmed message (if programmed) in form of numeric
code, vocal call or text message.
It is stored...
In the Event Log and the Diagnose Log.
4.3.13 Open input event
This is generated
when...
An input is opened.
It activates...
The programmed open input outputs associated to the zone to which the input belongs.
It is indicated …
On the open input LED of the keypads associated to the input.
On the red LED blinking on the readers if no alarms or failures/faults are being indicated.
4.3.14 Open input test event
This is generated
when...
A customised test input is opened.
It activates...
The programmed open input outputs associated to the zone to which the input belongs.
It is indicated …
On the open input LED of the keypads associated to the input.
On the red LED blinking on the reader if it is not already on fixed to indicate faults/failures or
alarms.
It is stored...
In the Event Log.
In the Diagnose Log.

Table of Contents

Other manuals for urmet domus 1067

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the urmet domus 1067 and is the answer not in the manual?

urmet domus 1067 Specifications

General IconGeneral
Brandurmet domus
Model1067
CategoryAntenna
LanguageEnglish

Related product manuals