SIP User's Manual 198 Document #: LTRT-65412
MP-11x & MP-124
5.2.2 Changing SSH Login Password
For security, it is recommended to change the default SSH Client login password, using the
SSH client.
¾ To change the SSH login password:
1. Open an SSH Client session (e.g. PuTTY), and then connect, using the default user
name and password ("Admin" - case sensitive), to the device. If a message appears
with the RSA host key, click Yes to continue; the shell prompt appears (“\> ”).
2. At the CLI prompt, type the command chpw and specify the existing and new
passwords.
chpw <old_password> <new_password>
where:
• <old_password> is the existing password
• <new_password> is the new password
The device responds with the message “Password changed”.
3. Close the SSH client session and reconnect using the new password.
Note: The default user name ("Admin") cannot be changed from within an SSH
client session.
5.3 Adding the Device in EMS
Once you have defined the IPSec communication protocol for communicating between
EMS and the device, and configured the device's IP address (refer to the device's
Installation Manual), you can add the device in the EMS.