Version 5.8 281 September 2009
SIP User's Manual 6. Configuration Parameters Reference
6.7.3 Profile Parameters
The profile parameters are described in the table below.
Table 6-31: Profile Parameters
Parameter Description
Coders Table
[CoderName]
This ini file table parameter defines the device's coders. This includes up to
five groups of coders (each group consisting of up to five coders) that can
be associated with IP or Tel Profiles ('Coder Group Settings' page in the
Web interface -- refer to ''Coder Group Settings'' on page 107). The firs
t
group of coders (indices 0 through 4) is the default coder list and default
coder group. The format of this parameter is as follows:
[CoderName]
FORMAT CoderName_Index = CoderName_Type,
CoderName_PacketInterval, CoderName_rate,
CoderName_PayloadType, CoderName_Sce;
[\CoderName]
Where,
 Type = Coder name
 PacketInterval = Packetization time
 Rate = Packetization rate
 PayloadType = Payload type
 Sce = Silence suppression mode
For example:
CoderName 0 = g711Alaw64k, 20,,,0;
CoderName 1 = g726, $$, 3, 38, 0;
CoderName 2 = g729, 40, 255, 255, 1;
The table below lists the supported coders:
Coder Name Packetization
Time (msec)
Rate
(kbps)
Payload
Type
Silence
Suppression
G.711 A-law
[g711Alaw64k]
10, 20
(default), 30,
40, 50, 60, 80,
100, 120
Always 64 Always 8 Disable [0]
Enable [1]
G.711 U-law
[g711Ulaw64k]
10, 20
(default), 30,
40, 50, 60, 80,
100, 120
Always 64 Always 0 Disable [0]
Enable [1]
EG.711 A-law
[eg711Alaw]
10 (default), 20 Always 64 Dynamic
(96-127)
N/A
EG.711 U-law
[eg711Ulaw]
10 (default), 20 Always 64 Dynamic
(96-127)
N/A
G.729
[g729]
10, 20
(default), 30,
40, 50, 60, 80,
100
Always 8 Always
18
Disable [0]
Enable [1]
Enable w/o
Adaptations [2]
G.722
[g722]
20 (default),
40, 60, 80,
100, 120
64
(default)
Always 9 N/A