SIP User's Manual 322 Document #: LTRT-65412
MP-11x & MP-124
Parameter Description
Charge Codes Table
[ChargeCode]
This ini file table parameter configures metering tones (and their time
intervals) that the device's FXS interface generates to the Tel side.
The format of this parameter is as follows:
[ChargeCode]
FORMAT ChargeCode_Index = ChargeCode_EndTime1,
ChargeCode_PulseInterval1, ChargeCode_PulsesOnAnswer1,
ChargeCode_EndTime2, ChargeCode_PulseInterval2,
ChargeCode_PulsesOnAnswer2, ChargeCode_EndTime3,
ChargeCode_PulseInterval3, ChargeCode_PulsesOnAnswer3,
ChargeCode_EndTime4, ChargeCode_PulseInterval4,
ChargeCode_PulsesOnAnswer4;
[\ChargeCode]
Where,
 EndTime = Period (1 - 4) end time.
 PulseInterval = Period (1 - 4) pulse interval.
 PulsesOnAnswer = Period (1 - 4) pulses on answer.
For example:
ChargeCode 1 = 7,30,1,14,20,2,20,15,1,0,60,1;
ChargeCode 2 = 5,60,1,14,20,1,0,60,1;
ChargeCode 3 = 0,60,1;
ChargeCode 0 = 6, 3, 1, 12, 2, 1, 18, 5, 2, 0, 2, 1;
Notes:
 The parameter can include up to 25 indices (i.e., up to 25 different
metering rules can be defined).
 This parameter is applicable only to FXS interfaces.
 To associate a charge code to an outgoing Tel-to-IP call, use the
'Tel to IP Routing' table.
 To configure the Charge Codes table using the Web interface, refer
to ''Configuring the Charge Codes Table'' on page 116.
 For an explanation on configuration using ini file table parameters,
refer to ''Format of ini File Table Parameters'' on page 191.
6.12 Telephone Keypad Sequence Parameters
The telephony keypad sequence parameters are described in the table below.
Table 6-50: Keypad Sequence Parameters
Parameter Description
Call Pickup
[KeyCallPickup]
Defines the keying sequence for performing a call pick-up. Call
pick-up allows the FXS endpoint to answer another telephone's
incoming call by pressing this user-defined sequence of digits.
When the user dials these digits (e.g., #77), the incoming call
from another phone is forwarded to the FXS user's phone.
The valid value is a string of up to 15 digits (0-9, #, and *).
Notes:
 Call pick-up is configured only for FXS endpoints pertaining
to the same Hunt Group ID.
 This parameter is applicable only to FXS interfaces.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
BrandAudioCodes
ModelMP-124
CategoryGateway
LanguageEnglish

Related product manuals