Set IPv6 Prefix Length Field
Procedure
Step 1
Unlock network configuration options.
Step 2
Set the DHCPv6 option to No.
Step 3
Scroll to the IPv6 Prefix Length option, press Edit, and then enter a new subnet mask.
Step 4
Press Validate and then press Save.
Set IPv6 Default Router 1 Field
Procedure
Step 1
Unlock network configuration options.
Step 2
Set the DHCPv6 option to No.
Step 3
Scroll to the appropriate Default Router option, press the Edit softkey, and then enter a new router IP address.
Step 4
Press the Validate softkey.
Step 5
Repeat Steps 3 and 4 as needed to assign the backup router.
Step 6
Press the Save softkey.
Set IPv6 DNS Server 1 and IPv6 DNS Server 2 Fields
Procedure
Step 1
Unlock network configuration options.
Step 2
Set the DHCPv6 option to No.
Step 3
Scroll to the appropriate DNS Server option, press Edit, and then enter a new DNS server IP address.
Step 4
Press Validate.
Step 5
Repeat Steps 3 and 4 as needed to assign the backup DNS server.
Step 6
Press Save.
Cisco Unified IP Phone 7941G, 7941G-GE, 7942G, 7961G, 7961G-GE, and 7962G Administration Guide for Cisco Unified
Communications Manager 9.0 (SCCP and SIP)
81
Cisco Unified IP Phone Settings
Set IPv6 Prefix Length Field

Table of Contents

Other manuals for Cisco 7941G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 7941G and is the answer not in the manual?

Cisco 7941G Specifications

General IconGeneral
Keypad number of keys12
Touchscreen-
Display resolution320 x 222 pixels
SpeakerphoneYes
Voice codecsG.729a
BluetoothNo
Supported network protocolsDHCP, TFTP, SCCP, DSCP
Ethernet LAN (RJ-45) ports2
Input voltage48 V
Dimensions (WxDxH)266.7 x 152.4 x 203.2 mm
Storage temperature (T-T)-10 - 60 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)10 - 95 %
Handset typeWired handset
Product typeIP Phone
Product colorGray
Safety(UL) 60950, (CSA) C22.2 No. 60950, IEC 60950, EN 60950, AS/NZS 60950
CertificationCE (FCC) 15 (CFR 47) B ICES-003 B EN55022 B CISPR22 B AS/NZ 3548 B VCCI B EN55024 EN 50082-1 EN 61000-3-2 EN 61000-3-3
Compliance industry standardsIEEE 802.3, IEEE 802.3u, IEEE 802.1Q, IEEE 802.3af
Lines quantity- lines
Phonebook capacity- entries
Number of handles included1 pc(s)
Weight and Dimensions IconWeight and Dimensions
Weight1600 g