Hard disk drives / solid state drives
7.2.2.5 Concluding steps
Perform the following procedures to complete the task:
Ê When working on a tower server, close the HDD bay cover as described in
section "Installing the HDD bay cover" on page 84.
Ê Please observe the notes on RAID rebuild in section "Performing a RAID
array rebuild" on page 117.
Ê If applicable, close the rack door as described in section "Closing the rack
door" on page 92.
7.2.3 Removing 2.5-inch HDD / SSD modules
7.2.3.1 Required tools
Preliminary and concluding steps: tool-less
Removing a 2.5-inch HDD / SSD module: tool-less
7.2.3.2 Preliminary steps
Before removing a 2.5-inch HDD / SSD module, perform the following steps:
Ê Ensure that the HDD / SSD module to be removed is not combined into a
RAID array. If the drive is part of a RAID array, you first need to delete the
array using ServerView RAID Manager.
V CAUTION!
All data on all HDDs / SSDs in the array will be lost! Be sure to back
up your data before deleting a RAID array.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide, available from the ServerView Suite
DVD 2 supplied with your PRIMERGY server or online at
Customer Replaceable Units (CRU)
Average task duration: 5 minutes

Table of Contents

Other manuals for Fujitsu PRIMERGY TX140 S1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX140 S1 and is the answer not in the manual?

Fujitsu PRIMERGY TX140 S1 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX140 S1
CategoryServer
LanguageEnglish

Related product manuals