172 Upgrade and Maintenance Manual TX140 S1
Hard disk drives / solid state drives
Ê Locate the defective HDD / SSD module as described in section "Local
diagnostic indicators on the front" on page 57.
Only applicable for removing intact HDD / SSD modules:
Ê Before removing a non-defective HDD / SSD module, put the drive into
"Offline" mode using your RAID configuration software.
7.2.4.3 Removing a 2.5-inch HDD / SSD module
Ê Remove the HDD / SSD module to be replaced from the server as described
in section "Removing a 2.5-inch HDD / SSD module" on page 168.
7.2.4.4 Installing a 2.5-inch HDD / SSD module
Ê Install the new HDD / SSD module into the empty drive bay as described in
section "Installing 2.5-inch HDD / SSD modules" on page 163.
7.2.4.5 Concluding steps
Perform the following procedures to complete the task:
Ê When working on a tower server, close the HDD bay cover as described in
section "Installing the HDD bay cover" on page 84.
Ê Please observe the notes on RAID rebuild in section "Performing a RAID
array rebuild" on page 117.
Ê If applicable, close the rack door as described in section "Closing the rack
door" on page 92.

Table of Contents

Other manuals for Fujitsu PRIMERGY TX140 S1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX140 S1 and is the answer not in the manual?

Fujitsu PRIMERGY TX140 S1 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX140 S1
CategoryServer
LanguageEnglish

Related product manuals