584 Upgrade and Maintenance Manual TX140 S1
Appendix
17.3.2.2 Front panel controls and indicators
Figure 408: Front panel controls and indicators
Local diagnostic indicators
I In addition to local dignostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer replaceable unit or if a
service technician needs to be dispatched to replace the part.
Pos. Indicator Status Description
1
HDD error
indicator
orange on
HDD / SSD, SAS / SATA backplane or
RAID controller failure detected
2
PSU error
indicator
orange on
Hot-plug PSU module failure detected
I Only available in redundant PSU
configurations.
3
Temperature
error indicator
orange on
Operating temperature levels above
permitted limits
4
CPU error
indicator
orange on CPU prefailure event detected
5
Memory error
indicator
orange on Memory module failure detected
6
Fan error
indicator
orange on Fan prefailure or failure event detected

Table of Contents

Other manuals for Fujitsu PRIMERGY TX140 S1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX140 S1 and is the answer not in the manual?

Fujitsu PRIMERGY TX140 S1 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX140 S1
CategoryServer
LanguageEnglish

Related product manuals