Troubleshooting SPCs on the SRX3600 Services Gateway
To troubleshoot an SPC, follow these guidelines:
•
Make sure the SPC is properly seated in the midplane and its screws are tightened.
•
Issue the CLI show chassis fpc command to check the status of installed SPCs. As shown in the sample
output, the value Online in the column labeled State indicates that an SPC in slot 2 is functioning normally:
user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
1 Empty 41 9 0 1024 15 57
2 Online 43 5 0 1024 16 57
3 Online 43 11 0 1024 16 57
4 Empty
5 Empty
6 Online 42 6 0 1024 16 57