EasyManuals Logo
Home>Juniper>Gateway>SRX3600

Juniper SRX3600 Hardware Guide

Juniper SRX3600
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #198 background imageLoading...
Page #198 background image
Uptime: 1 hour, 33 minutes, 43 seconds
For further description of the output from the commands, see the Junos System Basics and Services
Command Reference.
RELATED DOCUMENTATION
Troubleshooting with Chassis and Interface Alarm Messages on the SRX3600 Services Gateway | 177
Troubleshooting with the CLI on the SRX3600 Services Gateway | 175
Troubleshooting with LEDs on the SRX3600 Services Gateway | 176
Troubleshooting the Cooling System on the SRX3600 Services Gateway | 188
Troubleshooting IOCs and NP-IOCs on the SRX3600 Services Gateway | 189
Troubleshooting SPCs on the SRX3600 Services Gateway | 193
Troubleshooting the Power System on the SRX3600 Services Gateway | 195
Troubleshooting SPCs on the SRX3600 Services Gateway
To troubleshoot an SPC, follow these guidelines:
•
Make sure the SPC is properly seated in the midplane and its screws are tightened.
•
Issue the CLI show chassis fpc command to check the status of installed SPCs. As shown in the sample
output, the value Online in the column labeled State indicates that an SPC in slot 2 is functioning normally:
user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
1 Empty 41 9 0 1024 15 57
2 Online 43 5 0 1024 16 57
3 Online 43 11 0 1024 16 57
4 Empty
5 Empty
6 Online 42 6 0 1024 16 57
193

Table of Contents

Other manuals for Juniper SRX3600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX3600 and is the answer not in the manual?

Juniper SRX3600 Specifications

General IconGeneral
BrandJuniper
ModelSRX3600
CategoryGateway
LanguageEnglish

Related product manuals