SRX3600 Services Gateway NEBS and ETSI Compliance
IN THIS SECTION
SRX3600 Services Gateway NEBS and ETSI Standards | 316
SRX3600 Services Gateway NEBS and ETSI Configuration Requirements | 316
SRX3600 Services Gateway NEBS and ETSI Standards
The SRX3600 Services Gateway, when installed and configured as described in this section, meets the
following NEBS and ETSI standards:
•
GR-63-CORE
•
ETSI 300019-2-1
•
ETSI 300019-2-2
•
ETSI 300019-2-3
•
GR-1089-CORE
SRX3600 Services Gateway NEBS and ETSI Configuration Requirements
To meet the NEBS and ETSI standards described in “SRX3600 Services Gateway NEBS and ETSI Standards”
on page 316, the SRX3600 Services Gateway must be configured as follows:
•
The services gateway must be installed in an open two-post or four-post rack, and not in an enclosed
cabinet.
•
The services gateway must be installed in accordance with the instructions and procedures in this guide.
•
The services gateway must be equipped with four power supplies.
•
For AC-powered services gateways, all four power supplies installed in the device must be Revision 09
or later. You can determine the power supply version numbers by using the show chassis hardware
command. You can also identify the power supply version by referring to the printed label on the power
supply, which shows the version in an alphabetic format. Revision 09 corresponds to “REV 0F,” Revision
10 corresponds to “REV 0G,” and so on. Figure 91 on page 317 shows the location of the power supply
model and revision label.