Eligible Slots for SRX1400, SRX3400, and SRX3600 Services Gateway
Modules
Table 10 on page 30 summarizes the slots in which you can install each module type for SRX1400, SRX3400,
and SRX3600 Services Gateways.
Table 10: Supported Slots for SRX1400, SRX3400, and SRX3600 Services Gateway Modules
Supported Slots
Module Name and
Number SRX3600SRX3400SRX1400
Front slots labeled 1-6 and
rear slots labeled 7-12. We
recommend that you install
SPCs in rear panel slots to
leave room for IOCs in the
front panel slots.
See note below for additional
restrictions.
Front slots labeled 1-4
and rear slots labeled 5-7.
We recommend that you
install SPCs in rear panel
slots to leave room for
IOCs in the front panel
slots.
See note below for
additional restrictions.
Front slot labeled 1 (When
installed as primary SPC in
conjunction with an
SRX3K-NPC in slot 3)
Front slot labeled 2 (When
installed as second SPC)
“Services Processing Card
SRX3K-SPC-1-10-40” on
page 32
Rear slots labeled 10-12Rear slots labeled 5-7.Slot 3 (When installed as
the primary NPC in
conjunction with an
SRX3K-SPC in slot 1)
“Network Processing Card
SRX3K-NPC” on page 34
Front slots labeled 1-6, except
as noted below.
Front slots labeled 1-4,
except as noted below.
Slot 2“I/O Card
SRX3K-16GE-TX” on
page 36
“I/O Card
SRX3K-16GE-SFP” on
page 38
“I/O Card
SRX3K-2XGE-XFP” on
page 40
30