11. SERVICE MODE Field Service Ver. 2.0 Jun. 2010
88
bizhub 164
ADJUSTMENT / SETTING
11.3.11 FUSER TEMP. (PLAIN)
A. Use
•To set the temperature of the fusing roller for each type of paper, thereby making up for
fusing performance that changes with the operating environment or type of paper.
•Used when fusing failure occurs.
•Used when the type of paper is changed.
B. Procedure
•The default setting is 0.
-1 to +4
NOTE
•If +2, +3, or +4 is selected, the productivity decreases due to the paper feed inter-
val increased under the PPM control.
<Temperature table for adjusting fusing temperature for plain/recycle paper>
11.3.12 FUSER TEMP. (CARD1)
11.3.13 FUSER TEMP. (CARD2)
A. Use
•To set the temperature of the fusing roller for each type of paper, thereby making up for
fusing performance that changes with the operating environment or type of paper.
•Used when fusing failure occurs.
•Used when the type of paper is changed.
B. Procedure
•The default setting is 0.
-1 to +4
<Temperature table for adjusting fusing temperature for card 1/card 2>
Setting value
Difference from the target temperature determined by
the fusing temperature control
+4 +20 °C
+3 +15 °C
+2 +10 °C
+1 +5 °C
0 (default value) 0 °C
-1 -10 °C
Setting value
Difference from the target temperature determined by
the fusing temperature control
4+20 °C
3+15 °C
2+10 °C
1+5 °C
0 (default value) 0 °C
-1 -10 °C