11. SERVICE MODE Field Service Ver. 2.0 Jun. 2010
108
bizhub 164
ADJUSTMENT / SETTING
11.5.3 PM COUNTER
A. Use
•To display the count of the number of times each of different parts of the machine has
been used.
•This function is used at the time of maintenance work for the main body and options.
•The count should be cleared when the corresponding PM part is replaced.
B. Procedure
BYPASS : Each time a page is printed with paper from the bypass tray, the counter
increases by one.
TRAY1 : Each time a page is printed with paper from the tray 1, the counter
increases by one.
IR : Each time a page is copied with the use of the scanner, the counter
increases by one.
OZONE : If the paper length in the sub scanning direction is 216 mm or less, each
time a page is printed, the counter increases by one. If the paper length
in the sub scanning direction is over 216 mm, each time a page is
printed, the counter increases by two.
FUSING : If the paper length in the sub scanning direction is 216 mm or less, each
time a page is printed, the counter increases by one. If the paper length
in the sub scanning direction is over 216 mm, each time a page is
printed, the counter increases by two.
TRANSFER : If the paper length in the sub scanning direction is 216 mm or less, each
time a page is printed, the counter increases by one. If the paper length
in the sub scanning direction is over 216 mm, each time a page is
printed, the counter increases by two.
•To clear the count, use [CLEAR DATA] of the SERVICE MODE.
11.5.4 MAINTENANCE COUNT.
A. Use
•To display the count of the maintenance counter.
•When the counter reaches “0”, maintenance call M1 or the service call will appear,
according to the setting on MAINTENANCE COUNT. of SERVICE’S CHOISE.
See P.86
•To clear the count, use [CLEAR DATA] of the SERVICE MODE.
11.5.5 SUPPLIES COUNTER
A. Use
•To display the count of the supplies life counter.
•To clear the count, use [CLEAR DATA] of the SERVICE MODE.
B. Procedure
I/U Life : The value that corresponds to the amount of time for which the PC drum
has rotated is calculated and the value is subtracted from the initial counter
value of 55,000.
PH Start : Each time the polygon motor is started, the counter increases by one.
PH Turn : The amount of time for which the polygon motor has rotated is monitored
and the counter increases by one for every given period of time.