11. SERVICE MODE Field Service Ver. 2.0 Jun. 2010
92
bizhub 164
ADJUSTMENT / SETTING
11.3.20 GDI TIMEOUT
A. Use
•To specify the time for timeout when data from PC is interrupted during GDI printing.
B. Procedure
•The default setting is 60 sec.
5 sec/10 sec/20 sec/30 sec/40 sec/50 sec/“60 sec”
11.3.21 ERASER INSTALL
•Not used.
11.3.22 SUCTION FAN
A. Use
•To specify the length of time from when a print cycle is completed and until when the suc-
tion fan motor stops rotating.
•Used when image failure (while line etc.) occurs due to residual ozone that remains
around the drum.
B. Procedure
•The default setting is 2 sec.
“2 sec”/20 sec/ 60 sec/600 sec
NOTE
•Even when 20 sec. or more is selected in this setting, a higher priority is given to
the shift to sleep mode.
11.3.23 LANGUAGE GROUP
A. Use
•To select the language group applied to the firmware.
•To rewrite the firmware so that it can be used for a different marketing area.
B. Procedure
•The default setting varies depending on the marketing area.
TYPE 1/TYPE 2/TYPE 5/TYPE 6/TYPE7
•The new setting takes effect after the power switch is turned OFF/ON.