Automatic operation
1. Press
the reversing fan switch on the left control
panel to put the switch into “auto” position.
The machine will reverse the fan automatically
based on preset interval as long as automatic
operation is selected.
While the reversing fan is operating, a popup will
appear on the display.
Manual operation
1. Press and hold the reversing fan switch on the left
control panel to put the switch into "manual"
position.
The machine will reverse the fan while holding
down the switch.
While the reversing fan is operating, a popup will
appear on the display.
2. The switch will return to automatic operation when
released.
NOTE :
•
The fan will not reverse when fluid temperatures
approach overheating conditions. Cleaning or
servicing the cooling system may be required to
continue operation.
Reversing fan is disabled when the engine
coolant or hydraulic fluid temperature is too
high or too low.
20. Emergency engine stop button
IMPORTANT :
• Return
the stop button to its original position
after the engine stops.
The engine stops when the start switch is pushed off. If
the engine does not stop, pull the stop button to stop
the engine.
(1) Start switch (2) Emergency engine stop but-
ton
NOTE :
• If
the emergency engine stop button is
activated, a message will appear on the display
as shown in the following figure.