1. Check
to see if flammable material is deposited
around the DPF muffler.
If so, clean it out, otherwise a fire may result.
(1) DPF muffler
2. Check
the insulation of the DPF. If oil adheres to the
insulation of the DPF, replace the insulation.
15. Checking the washer liquid
If the window washer is switched on with the washer
liquid
tank empty, the motor may be damaged. Always
keep the tank filled.
(1) Washer liquid tank
IMPORTANT :
• The
washer-liquid-tank should be half filled
before working on a slope or a rough ground,
otherwise the liquid may leak out when the
machine bounces.
Half filled of the washer-liquid-tank about 0.8 liter
16. Checking the battery condition
DANGER
T
o avoid the possibility of a battery explosion: For
refillable type battery, follow the following
instructions.
• Do
not use or charge the refillable type battery
if the fluid level is below the [LOWER] (lower
limit level) mark. Otherwise, the component
parts of the battery may prematurely
deteriorate, which may shorten the service life
of the battery or cause an explosion. Check the
fluid level regularly and add distilled water as
required so that the fluid level is between the
[UPPER] and [LOWER] levels.
WARNING
T
o avoid personal injury or death:
• Never remove the vent caps while the engine is
running.
• Keep electrolyte away from eyes, hands, and
clothes. If you are spattered with electrolyte,
wash it away completely with water immediately
and get medical attention.
• Wear eye protection and rubber gloves when
working around the battery.
• Before inspection or dismounting the battery,
stop the engine and turn off the machine.
• When removing the battery, always disconnect
the negative ground cable first. When installing
a battery, always connect the ground cable last.
Connecting and disconnecting the cables in
proper order prevents a possible explosion
caused by sparks.
• Always wear eye protection when working with
the battery.
IMPORTANT :
• The battery of non-refillable type is factory-
installed. If the indicator turns white, do not
quick charge the battery but replace it with new
one.
Mishandling the battery shortens the service life of it
and adds to maintenance costs.
The original battery is maintenance free, but must be
checked periodically.
If the battery is weak, the engine will be difficult to start
and the lights will be dim. It is important to check the
battery periodically.
 MAINTENANCE DAILY CHECKS
160
SVL75-3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota SVL75-3 and is the answer not in the manual?

Kubota SVL75-3 Specifications

General IconGeneral
BrandKubota
ModelSVL75-3
CategoryCompact Loader
LanguageEnglish

Related product manuals