2GN/2GP/2GR-1
1-2-10
1. Enter 000 using the numeric keys and press the start key.
2. Select MAINTENANCE and press the start key to output a list of the current settings of the maintenance items.
3. Press the stop key.
1. Enter 001 using the numeric keys and press the start key. The machine exits the maintenance mode.
1. Select [Report Print] to output the user various setting reports.
1. Place an original and make test copies.
1. According to need, attach the correspond language label.
(2) Setting initial copy modes
Factory settings are as follows:
Maintenance
item No.
Contents Factory setting
U253 Switching between double and single counts Double count
U260 Selecting the timing for copy counting After ejection
U285 Setting service status page ON
U326 Setting the black line cleaning indication ON
U328 Side ejection setting OFF
U342 Setting the ejection restriction ON
U343 Switching between duplex/simplex copy mode OFF
Output an own-status report (maintenance item U000).
Exit maintenance mode.
Print out the user setting list.
Make test copies.
Attaching the language label (230 V specifications only).
Completion of the machine installation.