Power
Jetson AGX Xavier Series Product DG-09840-001_v2.5 | 23
Figure 5-6. Simplified Button Power-On Circuitry
BUTTON_POWER_ON*
SR C0GS 22 D
TDFN12
VCCLO*
VCC
PB OUTPSHOL D
SR* EN/ EN*
GND
INT*
PB*
CSRD
VRE F
R ST *
5V _A O_ON KEY
VIN_PWR_ON
5V _A O_ON KEY
CARRIER_PWR_ON
5V _A O_ON KEY
From Modul e
(Pin L62)
Fr om Powe r
But to n
VDDIN_PWR_BAD_N
5V _A O_ON KEY
5V _A O_ON KEY
5V _A O_ON KEY
MODULE_POWER_ON
From multiple
so ur ces (Mo du le
Pin L55)
VCC_SRC &
VDD_5V
enable.
15 0k
Ω, 1%
10uF
P ZP1 03BY
SO T32 3_
1G 1D1 S
0.1uF
0.1uF
1uF
NL17SZ08
DFT 2G SC7 0_5
G
S
D
G
S
D
P ZP1 03BY
SO T32 3_
1G 1D1 S
10 kΩ, 1%
0.47uF
5V _A O_ON KEY
POWER_BTN_N
SN 74LVC 1G
32 D CKR S C70
SN 74LVC 1G1 7
SC 70_ BUFF
SN 74LVC 1G0 7
[GW/DCKRE4]
SC 70_ 5
RB521 S30 T1G
RB521 S30 T1G
1uF
20 kΩ, 1%
10 0kΩ, 1%
To Module
(Pin L54)
To Module
(Pin L61)
10 0kΩ
VDD_5V
Optional ACOK circuit
See note
Notes:
1. To support auto-power-on or for a connection to a charger, see Figure 5-7.
2. Designs which implement an eFUSE or current limiting device on the input power rail of the
module should select a part that DOES NOT limit reverse current.
Table 5-3. Simplified Button Power Circuitry Timing
Timing Parameter Min Units
TDEBOUNCE Power button active duration >50 ms
5.4.1.1 Auto Power-On Option No MCU
For designs that will not have a power button but should power on when the main power
supply is connected, the optional ACOK circuit shown in Figure 5-7 should be implemented
and the
ACOK_L signal pulled to GND.