Phaser 6180MFP Multifunction Printer Service Manual 10-25
Plug/Jack and Wiring Diagrams
LVPS Over-Current Protection Circuit
This circuit stops all outputs if the power supply voltage 3.3 VDC, 5 VDC, or
24 VDC is shorted.
The circuit is reset, when after the cause of short was removed, the power is
turned Off, and then On again after certain time.
LVPS Over-Voltage Protection Circuit
This circuit stops all outputs, if the power supply voltage 3.3 VDC, 5 VDC, or
24 VDC exceeds the specified voltage respectively.
At this time, the operating point is 36 VDC or less for 24 VDC, 7 VDC or less
for 5 VDC, or 7 VDC or less for 3.3 VDC.
The circuit is reset when the power is turned Off, and then On again after
certain time.
Sleep Mode and Deep Sleep Mode
The output of the following power supply are stopped according to the signals.
Signal Line Name Description
LV TYPE Controls signal of the LVPS.
DEEP SLEEP
SLEEP
24V OFF
FAN STOP Drives control signal of the Main Fan.
FAN LOW
FAN ALARM
Signal
+3.3 VDC +5 VDC +24 VDC
Sleep On On On
Deep Sleep On On Off

Table of Contents

Other manuals for Xerox Phaser 6180MFP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox Phaser 6180MFP and is the answer not in the manual?

Xerox Phaser 6180MFP Specifications

General IconGeneral
BrandXerox
ModelPhaser 6180MFP
CategoryAll in One Printer
LanguageEnglish

Related product manuals