4 Individual remote controls
PC-ART
TCGB0106 rev.0 - 12/2014
123
4
4.2.5 Operation
Before operation
CAUTION
Turn on the electrical power supply to the system approximately 12 hours before start-up after a long shutdown. Do not start the sys-
tem immediately after connecting the power supply, because the compressor may be damaged if it is not sufciently heated.
Make sure the outdoor unit is not covered with ice or snow. If it is, remove the ice or snow with warm water (no hotter than 50°C). If
the water temperature is over 50°C, the plastic parts may be damaged.
When the system is started after being out of use for more than 3 months, we recommend that the system is checked by the service
provider.
If the system is not going to be used for a long period of time, turn it off at the mains. Otherwise it will continue to consume electricity,
since the oil heater remains on even when the compressor is off.
4.2.5.1 Operation mode selection procedure
Procedure for operation in cooling, heating, dehumidifying and ventilation modes
Switch on the power.
Two vertical lines are displayed on the LCD display together with the A/C or VENTI indications.
Press the MODE button.
By pressing this button repeatedly, the indicator will change from COOL to HEAT, DRY and FAN modes
(or from COOL to DRY and FAN in cooling only models).
(The gure shows the system status when COOL mode is selected).
Press the RUN/STOP button.
The run indicator will light up (green). The system will start up automatically.
NOTE
Setting the temperature, fan speed and louver direction: Once this setting is made it is stored in the
memory and therefore does not need to be set again every day. To change this setting, refer to the “Pro-
cedure for setting the temperature, fan speed and louver direction.” section.
Turn off (STOP)
Press the RUN/STOP button again. The run indicator (green) will go off. The system will stop automati-
cally.
NOTE
The fan may run for a further two minutes or so after stopping the system in heating mode.
Procedure for setting the temperature, fan speed and louver direction.
NOTE
If the OK button is pressed for more than three seconds in operation mode, the unit will switch to check mode (CHECK).
In check mode (CHECK), by pressing the OK button once the user can view the different variables using the TEMP or buttons.
To return to operation mode, press and hold OK for more than three seconds and then press OK twice.
Setting the temperature
Set the temperature by pressing the TEMP or buttons.
The temperature increases by 1 °C when the button is pressed (max. 30 °C).
The temperature decreases by 1 °C when the button is pressed (min. 19 °C for Cool, Dry and Fan
modes; minimum 17 °C for Heat mode)
(The gure shows the temperature set to 28 °C).

Table of Contents

Other manuals for Hitachi PSC-A1T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi PSC-A1T and is the answer not in the manual?

Hitachi PSC-A1T Specifications

General IconGeneral
BrandHitachi
ModelPSC-A1T
CategoryController
LanguageEnglish

Related product manuals