For
HP
Internal Use
Only
Table 5-4. System Fault Troubleshooting Procedure (continued)
CAUSE/SYMPTOM
ACTION
Determine
true
operating
state.
14.
PDC
prompt? I YES Reset system. Go
to
Step
16.
I
I -
NO. Replace
CPU
card. END
!
115.
OS
prompt?
YES. Perform orderly shutdown. Go
to
next step.
NO. Record chassis code and report
it
to
Response Center.
Refer
to
the
"Calling
the
Response Center" section for more
information. END
16.
Chassis codes change
YES. Unknown problem. Report
to
Response Center. Refer
to
appropriately?
the
"Calling
the
Response Center" section for more information.
END
NO Replace
CPU
card. Go
to
next step.
17.
Chassis codes change
YES.
END
appropriately?
NO Unknown problem. Report
to
Response Center. Refer
to
the
"Calling
the
Response Center" section for more information. END
Table 5-5. MPE/iX Halt 0 Operating System Error Codes
Code
Cause/
Action
0001
-
0099
Take memory
dump
and
call Response Center.
OOF1-
OOF3
Take memory dump. Replace
CPU
Card. May be OS bug.
OOF8-
OOFB
Take memory dump. Replace
CPU
Card. May be OS bug.
OOF4-
OOF7,
03xx
HPMC
may have occurred.
Perform a Transfer
of
Control (TOC). Perform a memory dump.
Refer
to
the
"Taking a Memory Dump" section for more information. Execute
PDC
PIM
HPMC
command from
the
PDC
Service menu
to
report HPMC error
log and
HPMC PIM.
Examine requestor/responder information
at
the
end
of
the
log and replace
the
1/0
card.
If
this does not solve
the
problem, replace
the
CPU
card.
If
the
problem persists, call
the
Response Center.
Refer
to
the
"Calling
the
Response Center" section for more information.
Troubleshooting 5-9