Internal Use Only
SCSI;Console;LAN PCA Access Port Error Codes.
This is a list of
the
error codes
that
can occur when
the
TA
command is used on
SCSI/Console/LAN
PCA,
P
/N
A1703-60003.
Table 5-39.
TA
Command Tests and Power-on Selftests
Test
Test
Description
Nmnber
1
OCT
ART
tests ( Never runs because oct
art
is always busy)
2 Flash ROM
test
3
Firmware
ROM
test
4
IODC
ROM
test
5
EEPROM
test
6
Local
port
ENQ/
ACK
test
7
Remote
port
ENQ/
ACK
test
8
LAN loopback
test
If
a test fails,
the
following message is displayed:
Additional
Failure
Information
TTTTSSSS
HHHHHHHH
HHHHHHHH
TTTT
is
the
first two bytes of the self test number in ASCII hex.
SSSS is
the
second two bytes of the self
test
number in ASCII hex.
HHHHHHHH
is for internal use only.
The
selftest failure test codes are shown in Table 5-40.
Troubleshooting 5-39

Table of Contents

Other manuals for HP 3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3000 Series and is the answer not in the manual?

HP 3000 Series Specifications

General IconGeneral
BrandHP
Model3000 Series
CategoryDesktop
LanguageEnglish

Related product manuals