KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual
4-5. Adjusting the Focus
<Procedure>
c lace the camera adjustment jig on the top surface of the calibration block, facing its etching
surface down.
d Loosen the hexagon socket head cap bolts c
and d (total of 6 locations) that secure the
camera, move the camera up and down, and
when lines up to 2 on the etching surface are
clearly visible (see the figure below), secure
the camera in position.
When the polarizing filter is adjusted to the
scale 0 (dark) position, the line can be seen
easily. After the adjustment has been
completed, return the polarizing filter to the
scale 5 (bright) position.
4-6
Rev. 2.10
カメ
E2106998000
(T110)
The lines around "2" shall be seen clearly.
CALロッ
Calibration block
②座金付六角穴付ボルト
SL6030892TN
(×2)
①座金付六角穴付ルト
SL6030692TN
(×4)
OCC
40001212
dWasher assembled
hexagon socket head
cap bolt
SL6030892
(
×
2
)
Camera adjustment jig
E2106998000 (T110)
cWasher assembled
hexagon socket head
cap bolt
SL6030692
(
×
4
)
OCC camera assembly
40001212