SLC™ 8000 Advanced Console Manager User Guide 209
11: Connections
Chapter 8: Device Ports on page 118 described how to configure and interact with an SLC
advanced console server port connected to an external device. This chapter describes how to use
the Devices > Connections page to connect external devices and outbound network connections
(such as Telnet or SSH) in various configurations.
An SLC unit port attached to an external device can be connected to one of the following
endpoints:
Another device port attached to an external device
Another device port with a modem attached
An outgoing Telnet or SSH session
An outgoing TCP or UDP network connection
This enables the user to set up connections such as those described in the next section. You can
establish a connection at various times:
Immediately. These connections are always re-established after reboot.
At a specified date and time. These connections connect if the date and time have already
passed.
After a specified amount of data or a specified sequence of data passes through the
connection. Following reboot, the connection is not reestablished until the specified data
passes through the connection.
Typical Setup Scenarios for the SLC Unit
Following are typical configurations in which SLC connections can be used, with references to
settings on the Devices > Connections and Device Ports > Settings web pages.
Terminal Server
In this setup, the SLC 8000 advanced console manager acts as a multiplexer of serial data to a
single server computer. Terminal devices are connected to the serial ports of the SLC unit and
configured as a Device Port to Telnet out type connection on the Devices > Connections page.
The users of the terminals can access the server as if they were connected directly to it by local
serial ports or a console.

Table of Contents

Other manuals for Lantronix SLC 8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC 8000 and is the answer not in the manual?

Lantronix SLC 8000 Specifications

General IconGeneral
Rack mountingYes
Console portRJ-45
Serial ports quantity48
USB 2.0 ports quantity2
AC input voltage120-230 V
Power source typeAC
AC input frequency50 - 60 Hz
Weight and Dimensions IconWeight and Dimensions
Weight5030 g
Dimensions (WxDxH)436.9 x 304.8 x 43.18 mm

Related product manuals