EasyManuals Logo
Home>Lantronix>Network Hardware>SLC 8000

Lantronix SLC 8000 User Manual

Lantronix SLC 8000
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #241 background imageLoading...
Page #241 background image
12: User Authentication
SLC™ 8000 Advanced Console Manager User Guide 241
Note: Older RADIUS servers may use 1645 as the default port. Check your RADIUS
server configuration.
Server #1 Secret Text that serves as a shared secret between a RADIUS client and the server (SLC
unit). The shared secret is used to encrypt a password sent between the client and
the server. May have up to 128 characters.
RADIUS Server #2 IPv4 or IPv6 address or host name of the secondary RADIUS server. This server
can be used as a SecurID proxy.
Server #2 Port Number of the TCP port on the RADIUS server used for the RADIUS service. If you
do not specify an optional port, the SLC 8000 advanced console manager uses the
default RADIUS port (1812).
Server #2 Secret Text that serves as a shared secret between a RADIUS client and the server (SLC
unit). The shared secret is used to encrypt a password sent between the client and
the server. May have up to 128 characters.
Timeout The number of seconds (1-30) after which the connection attempt times out. The
default is 30 seconds.
Use VSA Select the check box to obtain remote user attributes (group/permissions and port
access) from the RADIUS server via the Vendor-Specific Attribute (VSA). For
details on the format of the VSA, see User Attributes & Permissions from LDAP
Schema or RADIUS VSA on page 243.
Custom Menu If custom menus have been created, you can assign a default custom menu to
RADIUS users.
Escape Sequence A single character or a two-character sequence that causes the SLC unit to leave
direct (interactive) mode. (To leave listen mode, press any key.)
A suggested value is Esc+A (escape key, then uppercase "A" performed quickly
but not simultaneously). You would specify this value as \x1bA, which is
hexadecimal (\x) character 27 (1B) followed by an A.
This setting allows the user to terminate the
connect direct command on the
command line interface when the endpoint of the command is
deviceport,
tcp, or udp.
See Key Sequences on page 183 for notes on key sequence precedence and
behavior.
Break Sequence A series of 1-10 characters users can enter on the command line interface to send
a break signal to the external device. A suggested value is Esc+B (escape key,
then uppercase “B” performed quickly but not simultaneously). You would specify
this value as \x1bB, which is hexadecimal (\x) character 27 (1B) followed by a B.
Enable for Dial-back Select to grant a user dial-back access. Users with dial-back access can dial into
the SLC 8000 advanced console manager and enter their login and password.
Once the SLC device authenticates them, the modem hangs up and dials them
back. Disabled by default.
Dial-back Number The phone number the modem dials back on depends on this setting for the device
port. The user is either dialed back on a fixed number, or on a number that is
associated with the user’s login (specified here).
Data Ports The ports users are able to monitor and interact with using the connect direct
command. U1 and U2 denote the USB upper and lower ports on the front of the
SLC unit.
Listen Port
The ports users are able to monitor using the connect listen command.
Clear Port Buffers
The ports whose port buffer users may clear using the
set locallog clear
command.

Table of Contents

Other manuals for Lantronix SLC 8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC 8000 and is the answer not in the manual?

Lantronix SLC 8000 Specifications

General IconGeneral
Rack mountingYes
Console portRJ-45
Serial ports quantity48
USB 2.0 ports quantity2
AC input voltage120-230 V
Power source typeAC
AC input frequency50 - 60 Hz
Weight and Dimensions IconWeight and Dimensions
Weight5030 g
Dimensions (WxDxH)436.9 x 304.8 x 43.18 mm

Related product manuals