Motor OFF delay
0s
Pump 1
Threshold switch
Start at
Stop at
10.0
%
5.0
%
Not
enabled
Operation
4-66
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Motor (contd.)
Screen 3: Motor OFF Delay, Threshold Switch
Touch the key to move to the third setup screen.
Fig. 4-92 M4
Motor OFF Delay
The motor OFF delay supports overtravel when identifying the product, if
the sensor distance to the gun needs to be considered.
Fig. 4-93 Product identification
If this feature is not activated (delay = 0 s), the motor stops as soon as it is
switched off.
If the feature is activated, the motor continues to run for the set time after it
has been turned off via the interface Standard I/O.
NOTE: If the motor is switched on again via the interface Standard I/O
before the motor OFF delay has expired, the feature Motor OFF delay ends
immediately.
0 s