1
3
2
Installation
3-22
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Inert Gas
WARNING: Observe safety instruction regarding handling technical gas in
cylinders. The inert gas inlet pressure may not exceed 5.5 bar (550 kPa /
79.75 psi).
CAUTION: Use only suitable inert gas. Information can be obtained from
the Material Safety Data Sheet or the manufacturer of the material in the
tank.
The arrow points to the handwheel of the pressure controller.
Recommended setting: 0.3 bar / 30 kPa / 4.35 psi
1: Pressure display Inert gas
2: Safety valve for pneumatics
3: Connection Inert gas
The safety valve for pneumatics limits the inert gas inlet pressure to 2 bar
(200 kPa / 29 psi).
1