Troubleshooting
6-20
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Material Residue in Tank
Problem Possible Cause Corrective Action
Tank setpoint
temperature set too high
Correct temperature setting
Material of low quality or not
appropriate for application
(temperature resistance poor)
Consult material supplier
Material Hardens in Tank
Problem Possible Cause Corrective Action
Tank setpoint
temperature set too high
Correct temperature setting
Tank was not supplied
with inert gas
Check whether material supplier has
prescribed inert gas
With the option Inert gas
equipment
Inert gas bottle empty Replace
Inert gas control not activated Check software configuration code:
In box 22 there should be a G instead
of an X.
Check times for Gas on duration and
Gas off duration
Solenoid valve of inert gas
equipment defective
Replace
(The solenoid valve is in the melter
tower on the pressure display)
I/O board 1: Plug X7.1, X7.2 Check plug connection
I/O board 1 defective Replace

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson VersaBlue VB Series and is the answer not in the manual?

Nordson VersaBlue VB Series Specifications

General IconGeneral
BrandNordson
ModelVersaBlue VB Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals