Technical Data
9-1
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Section 9
Technical Data
General Data
Storage temperature
45 °C to +75 °C 49 °F to + 167 °F
Min. ambient temperature
5 °C + 23 °F
Max. ambient temperature
+ 50 °C +120 °F
Humidity 10 to 95 %, not condensing
Max. operating height 3000 m 9840 ft
Type of heating Cast-in electrical resistance heating elements
Possible temperature
sensors
Ni 120 (standard unit)
Pt 100 (optional)
Measuring precision
" 1 °C " 1 °F
(1 digit)
Material pressure (standard) 5 to 85 bar 500 to 8500 kPa 72.5 to 1233 psi
The pressure control valve is preset at the factory. Default:
35 bar 3500 kPa 508 psi
Degree of protection IP 54
Noise emission
(at a distance of 1 m)
1 motor: 62 dB(A)
2 motors: 65 dB(A)
3 motors: 66 dB(A)
4 motors: 68 dB(A)
Motor type 3 ph AC motor
Gear box type Helical gear
Motor/pump speed setting
range
1.0 to 100 min
-1
To prevent excessive wear, the motor/pump speed should not continu-
ously fall below 5 min
-1
(rpm) or continuously exceed 80 min
-1
(rpm).
Heatup time < 45 minutes
Melting capacity 1 tankfull per hour

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson VersaBlue VB Series and is the answer not in the manual?

Nordson VersaBlue VB Series Specifications

General IconGeneral
BrandNordson
ModelVersaBlue VB Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals