Technical Data
9-1
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Section 9
Technical Data
General Data
Storage temperature
−45 °C to +75 °C − 49 °F to + 167 °F
Min. ambient temperature
− 5 °C + 23 °F
Max. ambient temperature
+ 50 °C +120 °F
Humidity 10 to 95 %, not condensing
Max. operating height 3000 m 9840 ft
Type of heating Cast-in electrical resistance heating elements
Possible temperature
sensors
Ni 120 (standard unit)
Pt 100 (optional)
− Measuring precision
" 1 °C " 1 °F
(1 digit)
Material pressure (standard) 5 to 85 bar 500 to 8500 kPa 72.5 to 1233 psi
The pressure control valve is preset at the factory. Default:
35 bar 3500 kPa 508 psi
Degree of protection IP 54
Noise emission
(at a distance of 1 m)
1 motor: 62 dB(A)
2 motors: 65 dB(A)
3 motors: 66 dB(A)
4 motors: 68 dB(A)
Motor type 3 ph AC motor
Gear box type Helical gear
Motor/pump speed setting
range
1.0 to 100 min
-1
To prevent excessive wear, the motor/pump speed should not continu-
ously fall below 5 min
-1
(rpm) or continuously exceed 80 min
-1
(rpm).
Heatup time < 45 minutes
Melting capacity 1 tankfull per hour