Technical Data
9-2
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Temperatures
CAUTION: The maximum operating temperature of the installed gun and
the other heated system components should be considered when setting
temperatures on the melter control panel.
Min. operating temperature
+ 40 °C +100 °F
Max. operating temperature
+ 230 °C +450 °F
Overtemperature shutdown
by thermostat
+ 260 °C +480 °F
Shutdown by transformer
thermostat
+ 155 °C
(± 5 °C)
+311 °F
(± 9 °F)
Max. operating temperature
of filling valve (option)
+ 230 °C +450 °F
Pt100Ni120
Fig. 9-1 Hose receptacles