Parameter Value configured
The characters you can enter are ASCII
0x20-0x7e (31 bytes), but not "@" or "\".
The default is blank.
password "character string" You can specify the login for the Radius server.
Usable characters: ASCII 0x20-0x7e (128
bytes). The default is blank.
srvcert {on|off} You can set the server certificate. The default is
"off".
imca {on|off} You can enable or disable the certificate when
the intermediate certificate authority is present.
The default is "off".
srvid "character string" You can set the server ID and subdomain of the
certificate server.
Usable characters: ASCII 0x20-0x7e (128
bytes). The default is blank.
claer {a each command|all} Returns the selected setting to its default value.
If you specify "all", all settings will be restored to
their default values. However, IEEE 802.1x
Auth. status (enable or disable) for Ethernet and
wireless LAN will not be initialized.
access
Use the "access" command to view and configure access control. You can also specify two or more access
ranges.
View settings
msh> access
IPv4 configuration
msh> access [×] range "start-address end-address"
• [×] represents a target number between 1 and 5. (Up to five access ranges can be registered
and selected.)
Example: to specify accessible IPv4 addresses between 192.168.0.10 and 192.168.0.20:
msh> access 1 range6 192.168.0.10 192.168.0.20
5. Monitoring and Configuring the Printer
220