3.2
Box Menu
Box Menu Box Menu
Box Menu
3-12
[ARP TARGET MENU]
1 ARP SELECT
MANUAL 100/
AUTO 25/
AUTO 50/
AUTO 75/
AUTO 100
ALL CANCEL
NO/YES
2
3
REF TARGET VECTOR
OFF/ON
[ARP]
Table 3.2.7 ARP Box Menu
Menu Submenu Description
1 ARP SELECT
MANUAL 100/
AUTO 25/50/75/100
The FAR-2xx7 series can acquire a maximum of
100 targets, the number of auto/manual acquire
targets are determined by the ARP SELECT
setting.
For instance, AUTO-25 means 25 targets in the
automatic acquire and 75 targets in the manual
acquire.
2 ALL CANCEL NO/YES
Erases all ARPA targets.
3 REF TARGET
VECTOR
OFF/ON
When the setting is made as [SPD] box menu ->
1.SHIP SPEED -> REF, and when REF TARGET is
selected and acquired, this menu is used for turning
on and off the vector of the target. (Relative)