4.12 Change of Power Input Type
4-64
4.12 Change of Power Input Type
The power specifications are:
RPU-013: 100 VAC, 220 VAC, 24 VDC
MU-201CR and MU-231CR: 100 VAC to 220 VAC, 24 VDC
4.12.1 Changing AC Power Input
1. Jumper setting and adjustment
When changing the AC main type for the AC PWR board (03P9339A) and B (100 VAC),
and then C and D (220 VAC), it is required to make the setting of jumpers and make
adjustments of input overvoltage of this board.
Fig. 4.12.2 AC PWR Board
Table 4.12.1 Adjstment of over voltage protection circuit
FIL board
PWR board
J108
220 VAC: Open
100 VAC: Jumper between 1-2, 4-7, 5-8
R21: Adjustment of overvoltage VR
CR23INPUT ERROR
Fig. 4.12.1 Power Label of RPU-013
F1
- 100 VAC: 10 A (125 V)
- 220 VAC: 5 A (250 V)
- 24 VDC: 20 A (125 V)