Q & A
8-3
9. How many units can connect for the Inter-switch function?
See page.4-19, 4-21 and 4-23.
Up to four radars and up to four monitors can be connected. Make connections via
HUB-100. The related setting is made in [Menu] -> 0 -> 4 -> 4: RADAR NO. To
make the unit serve as Radar, assign 1 to 4 to the radar number. It is required for
this setting to change the IP address of Radar. When the setting is changed, be sure
to restart other FARs, CU-200, and HUB-100 connected to the LAN.
10. What kinds of operations are allowed when switching to another radar
by the Inter-switch?
See page.4-21 and 4-23.
The setting of GAIN, STC and RANGE can be changed. Echo processing of ES,
EAV, Echo trail and etc. is performed on the switched side.
Operation such as ARPA acquisition and tracking is performed on the original
processor unit. The inter-switch can perform operations such as target acquisition,
vector mode/time, tracking interval and TCPA/CPA on the side of units.
11. How to connect the external alarm
See page. 4-58 to 4-63.
There are four alarm output ports. An alarm event for alarm output can select in
[Menu] ->3 -> 6/7/8/9. When OPERATOR FITNESS is selected, other alarms
cannot be selected at the same port. The polarity of ALM-4 is inverted from those
of ALM-1, 2 and 3.
- ALM-1 to 3: Normal close
- ALM-4: Normal open
12. Is there any specific order in the connection of RCU-014, 015 and 016.
See page.7-71.
Connect the processor unit (RPU-013) with RCU-014 or RCU-015. Since
RCU-016 does not have a power switch, it cannot be directly connected to
RCU-013. Connect RCU-016 to RCU-014 or RCU-015.
13. How to install the De-icer
The De-icer is installed at factory. Please give instructions for the installation of
the De-icer in your purchase order of the equipment.
14. Can the FAR-2xx7 serve as a sub monitor?
See page.4-20, 4-23 and 4-81.
Connect the Master radar (Video, B.P, HD and trigger) to MASTER (J616) on the
TB board. Adjust R401 on the SPU board so that the level of TP58 on the SPU
board should be 2Vp-p.
When ON is selected in the setting of “8. SUB MONITOR” on the [ANT] box
menu, ANT-X and SUB can be switched in the [ANT] box.

Table of Contents

Other manuals for Furuno FAR-2827

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FAR-2827 and is the answer not in the manual?

Furuno FAR-2827 Specifications

General IconGeneral
BrandFuruno
ModelFAR-2827
CategoryMarine Radar
LanguageEnglish

Related product manuals