163
undo pim triggered-hello-delay
View
Interface view
Default level
2: System level
Parameters
interval: Maximum delay in seconds between hello messages, with an effective range of 1 to 60.
Description
Use pim triggered-hello-delay to configure the maximum delay between hello messages.
Use undo pim triggered-hello-delay to restore the default.
By default, the maximum delay between hello messages is 5 seconds.
Examples
# Set the maximum delay between hello messages to 3 seconds on VLAN-interface 100.
<Sysname> system-view
[Sysname] interface vlan-interface 100
[Sysname-Vlan-interface100] pim triggered-hello-delay 3
probe-interval (PIM view)
Syntax
probe-interval interval
undo probe-interval
View
Public network PIM view, VPN instance PIM view
Default level
2: System level
Parameters
interval: Register probe time in seconds, with an effective range of 1 to 1799.
Description
Use probe-interval to configure the register probe time.
Use undo probe-interval to restore the default.
By default, the register probe time is 5 seconds.
Related commands: register-suppression-timeout.
Examples
# Set the register probe time to 6 seconds in the public network.
<Sysname> system-view
[Sysname] pim
[Sysname-pim] probe-interval 6
# Set the register probe time to 6 seconds in VPN instance mvpn.

Table of Contents

Other manuals for HP 3600 v2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3600 v2 Series and is the answer not in the manual?

HP 3600 v2 Series Specifications

General IconGeneral
BrandHP
Model3600 v2 Series
CategorySwitch
LanguageEnglish

Related product manuals