9.2.4 Further process data
The parameters listed in the following can also be mapped to network registers, in order to
transmit control and status informaon as well as setpoints and actual values as process data.
Details
The following parameters are always available irrespecve of the network opon.
The use of these parameters for the transmission of process data is oponal. It is also pos-
sible to only use a part of the parameters. For the transmission of the frequency setpoint
and actual value, for instance, several parameters with a dierent resoluon can be selec-
ted.
Via the parameters, at the same me the general network acvity can be diagnosed.
NetWordIN1 ... NetWordIN5
These mappable data words are provided to individually control the inverter:
Data word Parameter Intended use
NetWordIN1 0x4008:001 (P590.01) For implemenng an individual control word format.
4General network sengs ^ 173
NetWordIN2 0x4008:002 (P590.02) For controlling the digital outputs via network.
4Conguraon of digital outputs ^ 415
NetWordIN3 0x4008:003 (P590.03) For controlling the analog outputs via network.
4Conguraon of analog outputs ^ 422
NetWordIN4 0x4008:004 (P590.04)
NetWordIN5 0x4008:005 (P550.05) For dening an addive voltage impression via network.
4Addive voltage impression ^ 323
NetWordOUT1 and NetWordOUT2
These mappable data words are provided to output status messages to the network master:
Data word Parameter Intended use
NetWordOUT1 0x400A:001 (P591.01) For implemenng an individual status word format.
4NetWordOUT1 status word ^ 419
NetWordOUT2 0x400A:002 (P591.02) For the output of messages of the "sequencer" funcon.
4Segment conguraon ^ 327
The following describes all further process data.
Conguring the network
Predened process data words
Further process data
196

Table of Contents

Other manuals for Lenze i510 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i510 Series and is the answer not in the manual?

Lenze i510 Series Specifications

General IconGeneral
Protection ClassIP20
Overload Capacity150% for 60 seconds
Enclosure RatingIP20
DimensionsVaries by model
WeightVaries by model
Control TypeV/f control, vector control
Communication InterfacesCANopen, Modbus RTU, EtherCAT, PROFIBUS, PROFINET
Ambient Temperature-10°C to +50°C
Braking ResistorOptional
SafetySTO (Safe Torque Off)
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature, short circuit
Output Voltage0 to input voltage
Input Voltage200-240 V, 380-480 V
Voltage Range200-240 V, 380-480 V
Frequency Range0 to 599 Hz