Parameter Name / value range / [default seng] Info
0x4016:004 Digital output 1: Switch-on delay
0.000 ... [0.000] ... 65.535 s
Switch-on delay for digital output 1.
Note!
The set delay me is not eecve (internally set to "0") if the relay is
assigned to the trigger "Release holding brake [115]". Only the decelera-
on me set in 0x2820:012 (P712.12)for closing the holding brake inu-
ences the me-dependent behaviour of the digital output.
0x4016:005 Digital output 1: Terminal state
Read only
Display of the logic state of output terminal X3/DO1.
0 FALSE
1 TRUE
0x4016:006 Digital output 1: Trigger signal state
Read only
Display of the logic state of the trigger signal for digital output 1 (without
taking a ON/OFF delay set and inversion into consideraon).
0 FALSE
1 TRUE
13.15.3 NetWordOUT1 status word
Assignment of digital triggers to bit 0 ... bit 15 of the NetWordOUT1 status word.
Details
The following table shows the preset status assignment of the NetWordOUT1 data word:
Bit Default seng For details and conguraon, see
0 Ready for operaon 0x2634:010 (P420.10)
1 Not connected 0x2634:011 (P420.11)
2 Operaon enabled 0x2634:012 (P420.12)
3 Error acve 0x2634:013 (P420.13)
4 Not connected 0x2634:014 (P420.14)
5 Quick stop acve 0x2634:015 (P420.15)
6 Running 0x2634:016 (P420.16)
7 Device warning acve 0x2634:017 (P420.17)
8 Not connected 0x2634:018 (P420.18)
9 Not connected 0x2634:019 (P420.19)
10 Setpoint speed reached 0x2634:020 (P420.20)
11 Current limit reached 0x2634:021 (P420.21)
12 Actual speed = 0 0x2634:022 (P420.22)
13 Rotaonal direcon reversed 0x2634:023 (P420.23)
14 Release holding brake 0x2634:024 (P420.24)
15 Safe torque o (STO) acve 0x2634:025 (P420.25)
The following parameters can be used to change the status assignment of the NetWordOUT1
data word.
Parameter Name / value range / [default seng] Info
0x2634:010
(P420.10)
Digital outputs funcon: NetWordOUT1 - bit 0
(Dig.out.funcon: NetWordOUT1.00)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 415
Assignment of a trigger to bit 0 of NetWordOUT1.
Trigger = FALSE: bit set to 0.
Trigger = TRUE: bit set to 1.
51 Ready for operaon
0x2634:011
(P420.11)
Digital outputs funcon: NetWordOUT1 - bit 1
(Dig.out.funcon: NetWordOUT1.01)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 415
Assignment of a trigger to bit 1 of NetWordOUT1.
Trigger = FALSE: bit set to 0.
Trigger = TRUE: bit set to 1.
0 Not connected
0x2634:012
(P420.12)
Digital outputs funcon: NetWordOUT1 - bit 2
(Dig.out.funcon: NetWordOUT1.02)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 415
Assignment of a trigger to bit 2 of NetWordOUT1.
Trigger = FALSE: bit set to 0.
Trigger = TRUE: bit set to 1.
52 Operaon enabled
Flexible I/O conguraon
Conguraon of digital outputs
Digital output 1
419

Table of Contents

Other manuals for Lenze i510 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i510 Series and is the answer not in the manual?

Lenze i510 Series Specifications

General IconGeneral
BrandLenze
Modeli510 Series
CategoryInverter
LanguageEnglish

Related product manuals