11.13 Timeout für fault reacon
If an error occurs that does not immediately cause a switch-o, the "Fault reacon acve"
device status becomes inially acve. The motor is brought to a standsll with quick stop
ramp. The change to the device status "Fault" is only made aer the quick stop (motor at
standsll) has been executed or aer an adjustable meout me has expired.
Details
In the device status "Fault reacon acve"
only the parameters of the inverter can be changed that do not require an inverter disable.
a holding brake in brake mode 0x2820:001 (P712.01) = "Automacally (via device state)
[0]" is triggered for closing.
the motor control connues to be operable.
Ready to
switch on
Not ready to
switch on
Switched
on
Operation
enabled
Fault reaction
active
Fault
Switch on
disabled
Quick stop
active
Power on
From all states
Power secon inhibited (pulse inhibit)
Power secon enabled
Diagnosc parameters:
0x282A:005 (P126.05) displays the current device status of the inverter
Parameter Name / value range / [default seng] Info
0x2826 Time-out for error response
0.0 ... [6.0] ... 100.0 s
This mer is started when a change-over to the "Fault reacon acve"
device status takes place. If the motor is sll rotang aer the me-out
me has elapsed, a change-over to the "Fault" device status takes place.
In case of a serious error, an immediate change-over to the "Fault"
device status takes place.
CAUTION!
Changing this parameter may cause a longer rampme in the event of an
error. This must be considered when changing this parameter.
Related topics
4Error handling ^ 90
4Automac restart ^ 312
Addional funcons
Timeout für fault reacon
311

Table of Contents

Other manuals for Lenze i510 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i510 Series and is the answer not in the manual?

Lenze i510 Series Specifications

General IconGeneral
Protection ClassIP20
Overload Capacity150% for 60 seconds
Enclosure RatingIP20
DimensionsVaries by model
WeightVaries by model
Control TypeV/f control, vector control
Communication InterfacesCANopen, Modbus RTU, EtherCAT, PROFIBUS, PROFINET
Ambient Temperature-10°C to +50°C
Braking ResistorOptional
SafetySTO (Safe Torque Off)
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature, short circuit
Output Voltage0 to input voltage
Input Voltage200-240 V, 380-480 V
Voltage Range200-240 V, 380-480 V
Frequency Range0 to 599 Hz

Related product manuals