EasyManuals Logo
Home>Lenze>Inverter>i510 Series

Lenze i510 Series Commissioning

Lenze i510 Series
487 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #364 background imageLoading...
Page #364 background image
13.2.6 Example 6: Enable inverter
This example shows how to use the "Enable inverter" funcon for a separate enable input.
In idle state of switch S1 (normally-closed contact), "Enable inverter" is already available.
Switch S2 starts the motor in forward rotang direcon (if switch S1 is closed). Switch S2 in
inial posion stops the motor again.
Switch S1 disables the inverter. The motor becomes torqueless (coasts).
Connecon plan funcon
GND
AI1
AI2
AO1
10V
24V
DI1
DI2
DI3
DI4
DI5
DO1
X3
S2S1
1k ...10k
0 ... 10 V
R1
Potenometer R1 Frequency setpoint selecon
Switch S1 Disable inverter
Switch S2 Run
Parameter Name Seng for this example
0x2631:001 (P400.01) Enable inverter Digital input 1 [11])
0x2631:002 (P400.02) Run Digital input 2 [12]
0x2631:004 (P400.04) Reset fault Not connected [0]
t
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
-40 Hz
-60 Hz
-50 Hz
-30 Hz
-20 Hz
-10 Hz
t
t
t
t
t
0x2DDD
Digital input 2 [12] Run
Digital input 1 [11]
Stop active [53]
Running [50]
Output signals
Status signals
Output frequency
Enable inverter
Input signals
Frequency setpoint selection
FunctionTrigger
The status signals can be assigned to digital outputs. 4Conguraon of digital outputs ^ 415
If the inverter is enabled and no error is acve, the motor can be started with the "Run" funcon in forward rotang direcon.
If "Enable inverter" is set to FALSE, the inverter is disabled. The motor becomes torqueless and coasts to standsll as a funcon of the mass
inera of the machine.
Without "Enable inverter", the motor cannot be started.
In the default seng, the motor does not start if the "Run" funcon is set to TRUE during "Enable inverter" . Aer "Enable inverter", must
be retriggered to start the motor.
4Starng performance ^ 103
Flexible I/O conguraon
Start / stop motor
Example 6: Enable inverter
364

Table of Contents

Other manuals for Lenze i510 Series